Search results for "width [beam]"

showing 10 items of 168 documents

High-rate x-ray spectroscopy in mammography with a CdTe detector: A digital pulse processing approach

2010

Purpose:Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. Methods: The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the respon…

Physicsbusiness.industryDetectorX-ray detectorGeneral MedicinePhoton countingFull width at half maximumOpticsQuality (physics)Ionization chamberSpectroscopybusinessNuclear medicineHalf-value layerMedical Physics
researchProduct

Laser Pulse Effects in Two-level Systems Driven by Coherent and Fluctuating Radiation Fields

1988

Abstract We reconsider the problem of a two-level system interacting with a radiation field in order to study some new features suggested by the actual experimental conditions. Pulse shape and duration effects are included in the formalism and the counter-rotating terms are retained. The criterion of validity of the rotating wave approximation (RWA) for pulsed fields is investigated; generalizing results well known in RWA, we establish some new formal results, including non-RWA contributions to all orders and for any pulse shape. The analysis is then carried out for fluctuating fields, by developing a method based on the theory of multiplicative stochastic differential equations. For short …

Physicsbusiness.industryDifferential equationMultiplicative functionAb initioRadiationLaserAtomic and Molecular Physics and Opticslaw.inventionStochastic differential equationOpticslawRotating wave approximationStatistical physicsbusinessPulse-width modulationJournal of Modern Optics
researchProduct

High performance 3D CZT spectro-imager for BNCT-SPECT: preliminary characterization

2018

The National Institute of Nuclear Physics (INFN) is supporting the 3CaTS project with the aim of developing a new Single Photon Emission Computed Tomography (SPECT) system for real time 10 B therapeutic dose monitoring in the binary experimental hadron therapy called Boron Neutron Capture Therapy (BNCT). BNCT is a highly selective tumour treatment based on the neutron capture reaction 10 B(n,α) 7 Li. The secondary particles have a high LET with ranges in tissues of the order of 10 μm (thus less than the mean cell diameter of few tens μm). Targeting the 10 B delivery towards cancer, the released energy lethally damages only the malignant cells sparing the normal tissues, thus enabling a cell…

Physicsmedicine.diagnostic_test010308 nuclear & particles physicsbusiness.industrySettore FIS/01 - Fisica SperimentaleDetectorResolution (electron density)Single-photon emission computed tomography01 natural sciencesSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)030218 nuclear medicine & medical imagingCharacterization (materials science)Hadron therapyBoron neutron capture therapy03 medical and health sciencesNeutron captureFull width at half maximum0302 clinical medicineOpticsSingle photon emission computed tomography.0103 physical sciencesmedicineNeutron irradiationbusinessX ray detector2018 IEEE Nuclear Science Symposium and Medical Imaging Conference Proceedings (NSS/MIC)
researchProduct

Investigation on pixellated CZT detectors coupled with a low power readout ASIC

2008

In this work, we investigated on the spectroscopic performances of two pixellated CZT detectors coupled with a custom low noise and low power readout ASIC. The detectors (10 x 10 x 1 mm3 and 10 x 10 x 2 mm3 single crystals) consist of an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 μm BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) characterized by a dynamic range from 10 keV to 100 keV, low power consumption (0.5 mW/channel) and low noise (150–500 electrons r.m.s.). The spectroscopic results point out the good energy resolution of both detectors at room temperature (5.8 % FWHM at 59.5 keV for the 1 mm thick detec…

PhysicssezelePhysics::Instrumentation and DetectorsDynamic rangebusiness.industryPreamplifierDetectorX-ray detectorTemperature measurementCathodelaw.inventionFull width at half maximumlawOptoelectronicsCharge carrierbusinessCZT detectors
researchProduct

Influence of pixel size on quantification of airway wall thickness in computed tomography.

2009

Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …

Pixelmedicine.diagnostic_testbusiness.industryPhantoms ImagingComputed tomographyField of viewBronchiBronchographycomputer.software_genreImaging phantomRadiographic Image EnhancementFull width at half maximumVoxelApproximation errorComputer GraphicsMedicineHumansRadiographic Image Interpretation Computer-AssistedRadiology Nuclear Medicine and imagingbusinessNuclear medicineTomography X-Ray ComputedImage resolutioncomputerSoftwareJournal of computer assisted tomography
researchProduct

A large-area scintillating fibre detector for relativistic heavy ions

1998

Abstract A scintillating fibre detector for relativistic heavy ions with an active area of 50 × 50 cm 2 has been developed and was tested with various ion beams (1 ≤ Z ≤ 92). At count rates of up to 10 5 particles/s, the position resolution was found to be determined by the fibre width of 1 mm; depending on the nuclear charge of the beam, efficiencies between 89% and 100% and time resolutions between 800 and 200 ps (FWHM) were obtained.

Position sensitive photomultiplierPhysicsNuclear and High Energy PhysicsFull width at half maximumPosition resolutionDetectorScintillating fibreAtomic physicsInstrumentationEffective nuclear chargeBeam (structure)IonNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Design and performance evaluation of a high power density EMI filter for PWM inverter-fed induction motor drives

2015

This paper presents the design of an electromagnetic interference (EMI) filter for a low voltage high current induction motor drives supplied by DC power grids, such as those used in several vehicle applications. In order to effectively design the EMI filter a suitable Common Mode/Differential Mode (CM/DM) separation technique has been used. In consideration of the high operating currents, a software based separation technique using time domain measurements has been applied. The proposed technique allows the CM and DM sections of the EMI filter to be properly selected in a more economical way, i.e. without the need of dedicated hardware or costly radio frequency (RF) instrumentation. The de…

Power DensityEngineeringEMI filterMotor drivebusiness.industryElectrical engineeringEnergy Engineering and Power TechnologyElectromagnetic interferenceCM and DM separation techniquesMotor driveSettore ING-IND/31 - ElettrotecnicaFilter (video)EMIElectronic engineeringCommon-mode signalCM and DM separation techniqueElectrical and Electronic EngineeringbusinessLow voltageInduction motorPulse-width modulation
researchProduct

The Evolution of Disk Winds from a Combined Study of Optical and Infrared Forbidden Lines

2020

We analyze high-resolution (dv=<10km/s) optical and infrared spectra covering the [OI] 6300 angstrom and [NeII] 12.81 micron lines from a sample of 31 disks in different evolutionary stages. Following work at optical wavelengths, we use Gaussian profiles to fit the [NeII] lines and classify them into HVC (LVC) if the line centroid is more (less) blueshifted than 30 km/s with respect to the stellar radial velocity. Unlike for the [OI] where a HVC is often accompanied by a LVC, all 17 sources with a [NeII] detection have either a HVC or a LVC. [NeII] HVCs are preferentially detected toward high accretors (Macc > 10$^{-8}$ Msun/yr) while LVCs are found in sources with low Macc, low [OI] …

Protoplanetary disks1300010504 meteorology & atmospheric sciencesInfraredFOS: Physical sciencesAstrophysics01 natural sciencesLuminosityStellar accretion disksStellar jets0103 physical sciences1607010303 astronomy & astrophysicsSolar and Stellar Astrophysics (astro-ph.SR)0105 earth and related environmental sciencesLine (formation)Earth and Planetary Astrophysics (astro-ph.EP)PhysicsSpectral index1579Astronomy and AstrophysicsAstrophysics - Astrophysics of GalaxiesRadial velocityFull width at half maximumWavelengthAstrophysics - Solar and Stellar Astrophysics13. Climate actionSpace and Planetary ScienceAstrophysics of Galaxies (astro-ph.GA)MagnetohydrodynamicsAstrophysics - Earth and Planetary Astrophysics
researchProduct

A General Mathematical Model for the Simulation of Common Faults in Three‐ phase Voltage Source Inverters

2013

In the last years the fault problem in power electronics has been more and more investigated both from theoretical and practical point of view. This paper analyzes the problem of faults modeling in a three phase voltage source inverter(VSI) and presents a model of a VSI able to simulate both unfaulty and faulty conditions when one or more devices go broken. In the past the fault problem was faced step by step considering the fault on each single device building a model for each case. The model hereafter presented solves this drawback through the introduction of the concept of the Healthy Device Binary Variable (HDBV) and the more general Healthy Leg Binary Variable (HLBV) showing also as th…

PulseWidth Modulated InvertersSettore ING-IND/32 - Convertitori Macchine E Azionamenti ElettriciFault‐toleranceNumerical modelFault
researchProduct

Direct Top-Quark Width Measurement at CDF

2010

7 páginas, 2 figuras, 2 tablas.-- CDF Collaboration: et al.

QuarkTop quarkParticle physicsJet energyAstrophysics::High Energy Astrophysical PhenomenaTevatronGeneral Physics and AstronomyFOS: Physical sciencesElementary particleddc:500.27. Clean energy01 natural sciencesBottom quark114 Physical sciencesHigh Energy Physics - ExperimentStandard ModelHEAVY QUARKS DECAY PHYSICSNuclear physicsPHYSICSHigh Energy Physics - Experiment (hep-ex)In-situ calibrationHeavy quarks0103 physical sciencesHigh energy physics010306 general physicsBosonsBosonPhysicsIntegrated luminosityQuark mass010308 nuclear & particles physicsPhysicsHigh Energy Physics::PhenomenologyConfidence levelsDecayUpper limitsDecay channelsTevatronThe standard modelFermilabHigh Energy Physics::ExperimentHEAVY QUARKSData sampleHEAVY QUARKS; DECAY; PHYSICSDECAYWidth measurementsColliderLepton
researchProduct